Voltammetric behavior and assay of the contraceptive drug levonorgestrel in bulk, tablets, and human serum at a mercury electrode.

2004

The cyclic voltammograms of levonorgestrel (LNG) in Britton-Robinson buffers of pH 2-11 at the hanging mercury drop electrode showed a single two-electron irreversible cathodic peak over the whole pH range. This peak may be attributed to the reduction of the 3-keto-delta-4-group in the A-ring of the LNG molecule. The interfacial adsorptive character of levonorgestrel onto the surface of the hanging mercury drop electrode was identified by means of both cyclic voltammetry and chronocoulometry techniques. A simple, sensitive, and selective square-wave adsorptive cathodic stripping voltammetric procedure was developed for the quantitation of levonorgestrel. Under the optimized operational cond…

Detection limitendocrine systemChromatographyChemistrychemistry.chemical_elementPharmaceutical formulationDropping mercury electrodeAnalytical ChemistryMercury (element)Hanging mercury drop electrodeCathodic stripping voltammetrymedicineLevonorgestrelCyclic voltammetrymedicine.drugTalanta
researchProduct

Digestion-free determination of heavy metals (Pb, Cd, Cu) in honey using anodic stripping differential pulse voltammetry and potentiometric stripping…

1995

Experiments have been carried out to assess the potential of differential pulse voltammetry and potential stripping analysis for determining Pb, Cu and Cd directly in dissolved honey samples using a flow-through cell. With the hanging mercury drop electrode Pb alone can be determined only if the electrode is first modified in-situ with Triton X 100 to increase the separation between the Pb peak and a broad, interfering adsorption peak which overlaps the Cu peak. If the (more sensitive) thin film mercury electrode is used the interference encountered is less so also Cu and Cd can be determined. With potentiometric stripping analysis Cu and Pb can be determined using normal procedures. The de…

Anodic stripping voltammetryAdsorptionStripping (chemistry)ChemistryHanging mercury drop electrodePotentiometric titrationOxidizing agentAnalytical chemistryfood and beveragesDifferential pulse voltammetryDropping mercury electrodeBiochemistryAnalytical ChemistryFresenius' Journal of Analytical Chemistry
researchProduct

Flow-through voltammetry (FTV) with the hanging mercury drop electrode (HMDE)

1995

A flow-through cell with integrated hanging mercury drop electrode for voltammetric, inverse voltammetric, adsorptive voltammetric, and chronoamperometric methods is described. HMDE droplets are automatically formed and renewed. By optimizing the flow-channel the sensitivity could be increased approximately five times in comparison with batch methods using the same deposition conditions.

ChemistryHanging mercury drop electrodeAnalytical chemistrychemistry.chemical_elementBiochemistryVoltammetryAnalysis methodAnalytical ChemistryMercury (element)Fresenius' Journal of Analytical Chemistry
researchProduct

Constant-potential electrolysis: determination of diffusion coefficients of thallium by using a hanging mercury drop electrode.

1976

The technique of constant-potential electrolysis at a stationary spherical electrode (hanging mercury drop) was investigated for the determination of the diffusion coefficient of Tl(I) in sodium citrate-sodium hydroxide medium and of Tl in mercury. Current-time curves, at controlled potential, were obtained, covering periods from 1 to 25 sec after the start of the electrolysis. The influence of applied potential, time of electrolysis, convection and shielding of the electrode was studied.

PolarographyElectrolysisDrop (liquid)Inorganic chemistryAnalytical chemistrychemistry.chemical_elementDropping mercury electrodeAnalytical ChemistryMercury (element)law.inventionchemistrylawHanging mercury drop electrodeSaturated calomel electrodeElectrodeTalanta
researchProduct